

The one capture system for more than one player. A good organ attracts many players. So SSOS's Multilevel Capture system lets each one store their personal piston settings without treading on the toes of others. Multilevel Capture can hold up to 512 levels of memory. Assign any number of these to an individual organist, and they're free to access the organ's memory without frantically searching their own. Crescendos and stepped sequences, too, can be stored at will.
Capture systems for all organs and organists. No two organs are the same. There again, nor are two organists. It's why SSOS make Multilevel Capture systems in a selection of sizes and specifications. Each one, of course can be added to later. And rest assured, the largest system is as straightforward to install as the most basic. MLC A, B, and C are based on three microprocessors developed specially by SSOS and proven over decades. As well as providing between 8 and 512 memory levels, they also feature "LIST" - a sequencer that allows organists to pre-arrange every combination in the order they're wanted for a whole performance. Powered by the new M3 processor with flash memory with no batteries to replace the new MUCAP system as we call it is designed with latest technology and is available as an upgrade to any system we have supplied.
|

Inputs to the system are positive and stop action outputs are also positive. On and Off coils are negative out and so require a positive return.
Voltages are 12 to 26-volt operation as standard. we can supply higher voltage systems if required.
Standard termination is by Krone punch block for rapid and reliable installation.
The system is supplied in racks of either 5, 10 or 20 cards, although custom sizes can be supplied to fit into a tight console space.
Block cards control up to 16 stops each and are connected to a pinboard shown on the right. A rack can control 16 cards each of which controls 16 stops although in reality they will not all be used due to grouping by divisions. If you require more stops simply add another rack which will automatically synchronise with the other for memory levels and piston sequencer controls.
Memory storage is with flash memory, systems with more than 8 levels use a Compact Flash card.
Removable memory USB storage is available using the Total Recall system.
The following links will open a Adobe pdf copy of the manual. If the file fails to open please visit www.adobe.com and download the free pdf reader.
Screen Resolution file: MultiLevel Capture Literature
High Quality Print file for presentations: MultiLevel Capture Literature
Demo brass control panel iPhone App (requires iTunes) MUCAP Control
Download: Format A Installation Manual
DownLoad: Format B,C and D Installation Manual
Download: Operation Manual